Key | Issue Type | Summary | Resolution | Note |
---|---|---|---|---|
PN-750 | Bug | Profinet Controller (IEC): Check Duplexity |
Fixed | |
PN-749 | Bug | Profinet Configurator: VLAN-ID Configurable |
Fixed | |
PN-747 | Bug | Profinet Controller: Activate Parameterization-Speedup |
Fixed | |
PN-745 | Bug | Profinet Controller: DHT Monitoring Fails |
Fixed | |
PN-744 | Bug | Profinet Controller: FSU Response time |
Fixed | |
PN-742 | Bug | Profinet Controller: Delayed Connect |
Fixed | [[GENERAL]] caused by PN-568 |
PN-741 | Improvement | PROFIsafe: F_Par_CRC Calculation for GSDML V2.45 |
Fixed | |
PN-739 | Improvement | Profinet Configurator: Upgrade Supported GSDML Schema |
Fixed | |
PN-736 | Improvement | Profinet Device (CIFX): Remove CAA Memory Block Manager |
Fixed | |
PN-724 | Bug | Profinet / RPC-Library: Fragmented RPC-Messages |
Fixed | |
PN-723 | Improvement | Profinet Controller: Set IP + Stationname in one Request |
Fixed | |
PN-719 | Improvement | Profinet Controller: PROFINET Device MAC |
Fixed | |
PN-718 | Bug | Profinet / WinV3: IO is updated slower than Send clock x Reduction Ratio |
Duplicate | [[GENERAL]] Duplicates PN-13 |
PN-717 | Bug | Profinet Configurator: Exception Selecting Negative Enumeration-Value |
Fixed | |
PN-715 | Bug | Profinet Controller (CIFX V3): Rework IO-Mapping |
Fixed | [[GENERAL]] caused by CDS-69793 |
PN-713 | Bug | PROFIsafe: SDD Builder generates safety device descriptions with F-parameter F_WD_Time_2 |
Fixed | |
PN-712 | Improvement | Profinet Configurator: GSDML DB should support relative paths |
Fixed | |
PN-707 | Bug | Profinet Controller (IEC): Online Change corrupts Unaligned IO-Data |
Fixed | |
PN-701 | Bug | Profinet (IEC): No LLDP Frames received (Dual-Port) |
Fixed | |
PN-700 | Bug | Profinet (IEC): Adjust I&M Data |
Fixed | |
PN-693 | Bug | Profinet - SNMP: Invalid Encoding of lldpRemIndex |
Fixed | |
PN-692 | Improvement | Profinet Device (IEC): Delay Connection Monitoring |
Fixed | |
PN-687 | Bug | Profinet Controller (IEC): Data-Record PDPortMrpDataReal Contains Wrong UUID |
Fixed | |
PN-685 | Bug | Profinet Device (IEC): Handling of Corrupted Alarm-Sequences |
Fixed | |
PN-677 | Bug | Profinet (IEC): MAC / SNMP-String Conversion fails |
Fixed | [[GENERAL]] caused by PN-124 |
PN-645 | Improvement | Profinet (IEC): Use SysEthernetLEDBlink |
Fixed | |
PN-638 | Improvement | Profinet Controller: Diagnosis API for PROFIsafe Submodules |
Fixed | |
PN-636 | Bug | Profinet Configurator: Allowed values not shown for Device's Settings |
Won't Fix | [[GENERAL]] As designed: Value ranges are displayed for normal numerical vales, but for enumerations the selectable values are provided in a ComboBox (as a list of textual values) |
PN-621 | Improvement | PROFIsafe Configuration: Configure F-Source Address for All Devices in One Step |
Fixed | |
PN-558 | Epic | Profinet Controller (IEC): Certificate on Virtual PLC |
Fixed | |
PN-419 | Bug | Profinet Configurator: Bug in allocation of IP Range when subnet mask <> 255.255.255.0 |
Fixed |